These utilities read raw device properties directly from a front end over an existing ACNET connection. They do not resolve device names, scale values, interpret status bits, or implement SETS32/SETDAT writes.

Use pacsys.acnet.gets32.Gets32Client or pacsys.acnet.retdat.RetdatClient. The common ReadDevice, ReadValue, and ReadStream types are available from both modules and from pacsys.acnet.

Addressing and data

A ReadDevice(di, pi, ssdn, length, offset=0) specifies a property-device index pair, an eight-byte SSDN in wire order, and a byte range. Requests target one front-end node. All entries use the same acquisition event; their order and duplicates are preserved. GETS32 uses 32-bit length/offset fields; RETDAT uses 16-bit fields.

The protocols do not identify the data type. Integers, floating point values, arrays, text, status words, alarm blocks, and device-specific structures are returned as ReadValue(status, data) objects. Each data contains the complete word-aligned wire slot, including padding for odd lengths (the RETDAT protocol notes describe systems where padding can precede the last data byte). Data accompanying a nonzero device status may be invalid; the original bytes and status are preserved.

Immediate reads

M:OUTTMP is a two-byte reading on MUONFE:

from pacsys.acnet import AcnetConnectionTCP, Gets32Client, ReadDevice

with AcnetConnectionTCP("acsys-proxy.fnal.gov") as conn:
    node = conn.get_node("MUONFE")
    device = ReadDevice(27235, 12, bytes.fromhex("000042003f210000"), length=2)
    client = Gets32Client(conn)
    reply = client.read(node, [device], timeout=1.0)
    print(reply.header.global_status, reply.values[0].status, reply.values[0].data.hex())

The clients also accept AcnetConnectionUDP. TCP access requires a proxy that permits GETS32/RETDAT tasks; clx and many central nodes restrict these tasks. On a restricted node, use AcnetConnectionUDP with its local acnetd. See TCP connection restrictions.

read() requests one batch and cancels on success, timeout, or error. Its timeout bounds the wait for data after request setup; the connection's command/ACK timeout still applies to setup. Device and GETS32 global error statuses remain in the result. Negative outer ACNET statuses raise AcnetError.

Acquisition events

GETS32 standard event strings are canonicalized before transmission:

Event Meaning
I Immediate, one reply
P,500 Periodic, every 500 ms
P,500,false Periodic without requesting an initial immediate notification
Q,500,true Poll every 500 ms and return on data change
E,02 Clock event 02, canonicalized to E,2,E,0
E,02,H,100 Hardware clock event with a 100 ms delay
E,02,S,100 Software clock event with a 100 ms delay
S,V:CLDRST,9,1000,= State announcement equal to 9, delayed by 1 second
S,134679,0,0,* Any announcement from state device index 134679
N Never; no acquisition data is expected

Standard clock events are hexadecimal 00–FF. Larger values are rejected because the reference frontend parser keeps only the low byte (E,100 would become event 00). Frontend-specific extended events require explicit Gets32Event(...) construction and support from the destination.

State comparisons support =, !=, *, <, >, <=, and >=. A state event listens to state announcements; it does not poll arbitrary basic-status bits. Q is the separate change-only acquisition mode. Support for each event is determined by the front end. There is no client-side polling emulation or protocol fallback. Client surfaces front-end rejections. Note that U requires database defaults and is rejected by this low-level utility.

For legacy or frontend-specific event strings, construct Gets32Event(text, classic_ftd, repetitive) explicitly. The text is transmitted verbatim, with protocol space padding. Use classic_ftd=-1 when the event has no complete classic FTD representation. This escape hatch validates wire bounds and ASCII encoding, not the frontend's event grammar.

RETDAT takes an explicit unsigned 16-bit ftd. Zero requests immediate data; periodic FTDs specify 60 Hz ticks (30 = 500 ms); 0x8000 | event_number selects a clock event. Legacy/reserved bits are transmitted unchanged. No GETS32 event string is silently reduced to a RETDAT event. The ACNET multiple-reply flag is set by stream() and cleared by read(), independently of the FTD.

Streams

from pacsys.acnet import AcnetConnectionTCP, Gets32Client, ReadDevice

device = ReadDevice(27235, 12, bytes.fromhex("000042003f210000"), length=2)
with AcnetConnectionTCP("acsys-proxy.fnal.gov") as conn:
    client = Gets32Client(conn)
    node = conn.get_node("MUONFE")
    with client.stream(node, [device], event="P,500") as stream:
        for reply in stream.readings(timeout=5.0):
            print(reply.values)

For RETDAT, use RetdatClient(conn) and stream(node, [device], ftd=30). For a single clock-triggered acquisition, use GETS32 read(..., event="E,02") or RETDAT read(..., ftd=0x8002), allowing enough time for that event to occur.

readings(timeout=...) validates the timeout immediately and starts its deadline when iteration begins. The timeout bounds the whole iteration, including consumer delays and queued data. It raises AcnetTimeoutError on expiry; timeout=None waits until closure or a terminal reply. Pending heartbeats do not yield data or extend the deadline. Only one iterator may consume a stream at a time.

The reply buffer defaults to 256 batches; buffer_size sets its capacity. Overflow cancels acquisition and raises BufferError after already-buffered batches are consumed. Other terminal errors likewise follow queued data. close() discards queued batches and wakes blocked readers. Always close streams or use a context manager, especially when ending iteration early.

Reply metadata

GETS32 preserves the global status, type/version/order fields, sequence number, and native cycle, collection, and reply time fields in Gets32Header. Timestamps normally use epoch milliseconds, but the cycle field can instead contain a UCD sequence number with a zero high word. The client does not guess which is present.

Both result types record the outer acnet_status and local callback receipt time as Unix nanoseconds (received_at_ns). RETDAT supplies no collection timestamp. The pure parse_reply() functions leave transport metadata as None unless supplied.

Each module also exposes build_request() and parse_reply() for direct wire work.

Message-size limits

Both clients accept keyword-only max_request_size and max_reply_size, each defaulting to 8,320 bytes, the conservative DPM frontend default. These limits include GETS32/RETDAT headers, per-device statuses, and padding, but exclude ACNET, UDP, and IP headers. The same keywords are available on both build_request() functions.

# Set limits appropriate for every destination used with this client.
client = Gets32Client(conn, max_request_size=16_384, max_reply_size=60_000)

For example, one GETS32 entry containing 40,000 raw bytes needs a reply limit of at least 40,036 bytes (34-byte reply header and 2-byte device status). Raising the reply limit does not require raising the request limit: the request itself only describes the byte range.

Limits must be positive integers. The supported transport ceilings are 65,484 request bytes and 65,488 reply bytes; larger configured limits are rejected at construction or encoding. These account for the local UDP send-with-timeout command and acnetd's network packet limit, respectively. Requests are never sent when their encoded size or expected reply size exceeds the configured limit.

Frontends may impose smaller limits. Raising a client limit does not negotiate support with the destination or assemble multiple replies automatically. Arrays that exceed the destination's capacity need explicit byte-range requests.